A. Requirements
Et 9L-EPs insulated arca archa debet ponere internum temperatus est 0 ℃ pro magis quam XXXVI horas in constant temperatus environment of XXXII ℃.
B. configuratione parametri
I. basic notitia de EPs insulated arca + glacies sarcinas
Notitia type | Details |
EPs insulated arca | Externi dimensiones (mm) CCCLXXV * CCCXLV * CCCXV |
Ice Pack quantitas (parametri): | XII pieces (500g 0 ℃ biological glacies sarcinas) |
Efficens magnitudine mm (Volume l): | CCXXX * CC * CXCV (9L) |
EPs insulated buxum pondus (kg): | 0.48 kg |
EPs insulated arca + XII glacies sarcinas totalis pondus (kg): | 0.48 + 6.0 6.48 kg |

II. Basic notitia de EPs insulated arca + glacies sarcinas
Notitia type | Details |
EPs arca externa dimensiones (mm): | CCCLXXV * CCCXLV * CCCXV |
EPs arca murum crassitudine (mm): | 40 |
EPs arca interna dimensiones (mm): | CCXCV * CCLXV * CCLV |
EPs Box volumine (L): | XX l |
EPs Box Pondus (KG): | 0.48 kg |
III. Basic notitia glacies sarcinas
Notitia type | Details |
Ice Pack Dimensiones (mm): | CCX * CXXXV |
Ice Pack tempus Mutare Point (℃): | 0 ℃ |
Glacies Pack Pondus (kg): | 0.5 kg |
Ice Pack quantitas (PCs): | XII 个 |
Totalis glacies sarcina pondus (kg): | 6.0 kg |
C. test results
Test curva et data Analysis:

In test environment of 27.7 ~ 33.3 ℃ (mediocris 31,1 ℃), in Varie Duration ad varias puncta est ut sequitur:
Locus | Duratio maintaining 0 ~ X ℃ (horas) |
Imo | 45.1 |
Centro | 44,8 |
Top | 39 |
D. test conclusioni
In test environment of 27.7 ~ 33.3 ℃ (mediocris 31.1 ℃), 9L-EPS (0 ~ X ℃) insulated buxum, quod internum temperatus 0 ~ X ℃ pro XXXIX horas.